Description
A container-scale lot: 300 Bitmain Antminer S19 units at 95 TH/s each, sold tested and working. That is roughly 28.5 PH/s of SHA-256 and around 975 kW of connected load. Nobody buys 300 miners on impulse, so here are the numbers you actually need to plan a site.
Per-unit specifications (Antminer S19 95TH/s)
| Hashrate (factory) | 95 TH/s ±5% |
|---|---|
| Power at the wall (factory) | 3,250 W ±5% |
| Efficiency (factory) | 34.2 J/TH |
| Algorithm | SHA-256 (Bitcoin) |
| ASIC chip | BM1398BB, 7 nm |
| Hashboards | 3 boards × 76 chips = 228 chips |
| Power supply | Integrated APW12 |
| Input voltage | 200–277 V AC |
| Cooling / noise | 4 fans, approx. 75 dB |
| Operating temperature | 5–40 °C |
| Dimensions / weight | 400 × 195.5 × 290 mm bare, 570 × 316 × 430 mm boxed. 14.2 kg net, 16 kg gross — Bitmain’s published S19 specification (model 240-Ca). Freight is billed on the gross weight, not the net |
| Network | Ethernet (RJ45) |
What’s in the box
- 300 × Bitmain Antminer S19 95TH/s — this listing is the whole lot, not one machine from it
- Nothing that is not listed above. Cords, controllers, brackets and spares are only included when this listing names them — if you need to know before you pay, ask on +1 (781) 577-0377 or ns@ingmining.com and we will confirm in writing what is physically in the crate
What 300 units means at the site level
| Total hashrate | Approx. 28.5 PH/s (300 × 95 TH/s, factory rating) |
|---|---|
| Total connected load | Approx. 975 kW (300 × 3,250 W, factory rating) |
| Heat rejected | Effectively all of it — plan roughly 975 kW of ventilation or heat reuse |
| Fleet efficiency | 34.2 J/TH |
Those are arithmetic from the factory ratings, not a promise about these specific machines. Real fleets run a spread: some units come in under rating, a few will need a board. Budget for it.
Condition
Sold as tested and working. That is our working-order grade, not a refurbishment — it means the units hashed when tested, not that they were rebuilt. Cosmetic condition varies across a lot this size, and on any 300-unit purchase you should expect a small number of units to need attention on arrival. Ask us about the test methodology, the pass criteria and the DOA policy on this lot before you commit. Boards, fans, PSUs and control boards for anything that does fail are in repair parts & tools.
Logistics
At the Bitmain-published S19 specification net weight of 14.2 kg per unit this is roughly 4.26 tonnes of hardware bare, and about 4.8 tonnes gross once boxed at 16 kg a unit — palletised freight, not parcel, and the quote is priced on the gross weight. Talk to us about freight, palletisation, staging and delivery windows before you order; on a lot this size the freight and the receiving plan are a real part of the deal. Smaller lots of 20, 40 and 50 units are also available if you want to start smaller.
Power and siting — read this before you buy
An S19 is a 200–277 V AC machine. It will not run on a standard North American 120 V outlet, and at roughly 3.25 kW it needs a dedicated 240 V circuit with real headroom — a 20 A 240 V breaker per machine is the practical floor. It is also a genuinely loud industrial appliance at about 75 dB. This is a shed, garage, warehouse or hosted-facility miner, not a living-room miner. If you want something you can put in a house, look at the Avalon Q instead.
Buying from ING Mining
We buy, repair, host and resell this hardware ourselves, so ask us the awkward questions before you order — power draw at the wall, board revision, what the fans sound like in a garage. Browse the rest of the catalogue at all miners.
Questions buyers ask about this lot
Will this run on a normal household outlet?
No. This lot needs a dedicated 200–277 V circuit. A North American 120 V household outlet will not run it under any adapter or configuration. Have an electrician confirm the supply before the pallet arrives.
What can I mine with it?
The algorithm is SHA-256 (Bitcoin), and ASIC silicon is single-purpose: it will mine coins on that algorithm and nothing else, whatever the price of anything else does.
What condition is it in, and what does that grade mean?
This is second-hand stock. We describe it the way we found it: tested working means it ran on our bench at the stated hashrate, refurbished means it was also cleaned, re-pasted or had parts replaced, and as-is means it is sold without a working claim. The grade for this unit is stated in the description above; where a listing states no grade, it says so rather than implying one. Cosmetic wear — dust, scratches, label marks — is normal on hardware that has been mining and is not a fault.
What should I check the day it arrives?
Photograph the pallet or box before you open it, keep the packaging, and run the 48-hour acceptance test straight away. Freight claim windows are short, and a fault found on day two is a conversation while a fault found on day thirty is an argument. Our own six-step bench procedure is published in full, so you can repeat exactly what we did.
Shipping cost for this exact item, and how warranty and returns work here, are answered in the Shipping & buying tab on this page. Anything else, ask a person on +1 (781) 577-0377 or ns@ingmining.com — we would rather talk before you buy.
Three hundred machines is a megawatt, and it is bought as one
About 975 kW of connected load is near enough a megawatt that the megawatt is the unit of purchase. On the hashprice derived at block 961,911 on 10 August 2026 on used ASIC miner fleet economics, a megawatt of stock 95 TH/s used S19s returns its purchase price in about 145 days at three cents a kilowatt-hour — and never at five or seven, because above their own 3.89-cent break-even the machines are under water. A megawatt of new SealMiner A2 Pro takes about 777 days at three cents but survives up to about 8.94 cents. That is the used-versus-new trade at this scale, and it is a choice between a fast return in a narrow power band and a slow return in a wide one, not a pitch.
The operational constraint at three hundred is that you cannot bench a pallet as fast as a pallet arrives. Acceptance testing is limited by the power you can energise at once — into a 200 kW service that is about sixty machines at a time, so a full pass is a queue several days long while the carrier’s concealed-damage window runs on a calendar. Plan the two against each other before the truck is booked, not after it is unloaded, and sample across the stack rather than off the top.
Tested and working means these hashed when they were tested. That is a working-order grade rather than a refurbishment, and cosmetic condition varies across a lot this size — ask us for the test methodology and the pass criteria, and settle the dead-on-arrival window and remedy in writing before the order goes in. What the word commits us to is defined on bulk used ASIC miners, and the freight, condition and repair-cost dataset behind a lot this size is published at used ASIC lot data.
Related hardware and where this sits in the store
Other fleet lots and single units from the same family:
- Lot of 40 Used Bitmain Antminer S19 95TH/s Miners
- Lot of 50 Refurbished Bitmain Antminer S19 95TH/s Miners – VNish OS
- Lot of 20 Refurbished Bitmain Antminer S19 110TH/s Miners – Boosted, VNish OS
Categories: Bitmain Antminer, Bitcoin miner, Used ASIC miners and Air Cooling.
Three hundred S19s is roughly 28.5 PH/s, about 975 kW of continuous load and over four tonnes of freight. Our used-miner buying guide works exactly this lot through as its fleet example, including testing methodology and DOA terms to agree in advance.
Delivery day on a lot this size is its own procedure — what to write on the freight receipt before you sign, reconciling the count and the serial numbers, why the machines come up in groups rather than together, and how to sort the ones that do not: receiving a used miner lot.





Reviews
There are no reviews yet.